GTHT

Stabilizer Inside Dual Comfort

Daikin GTHT Dual-Comfort series provides a 2-in-1 functionality - be it the scorching summers or the chilly winters, Daikin GTHT series would save you from the vagaries of fluctuating temperatures all year round. Along with Power Chill Mode that assists with Dual Flap Flattening for Faster Cooling, the series also features Daikin’s patented Streamer Discharge Technology for a smell-proof operation. The GTHT series also comes with the stabilizer-free operation which means that the AC can work steadily and reliably without getting damaged due to excessive flow of electricity in case of voltage fluctuations. Save on your utility bills while experiencing utmost comfort with the Daikin GTHT series.

Product category:

Available in (kW):

Color: 
White

Salient Features

Coanda airflow

Coanda airflow
Make way for effective air circulation and efficient temperature distribution with Daikin’s Coanda airflow, designed to give the best air-conditioning experience. This function ensures cooling at corners of the room by streaming cool air upwards along the ceiling avoiding furniture or obstruction.

Econo mode

Econo mode
Set the limit for power consumption with Daikin's ECONO mode feature. This function enables efficient operation by limiting the maximum power consumption. This mode is one step towards Daikin's future innovation.

Heating function till 4°C ambient

Heating function till 4°C ambient
Say goodbye to high electricity bills and welcome comfortable cooling in summers and effective heating in winters. Daikin air conditioners provide the best that air conditioning has to offer. From hot summers to cold winters, it ensures perfect temperature in your home all year along. Daikin air conditioners can perform heating operations down to ambient temperatures of 4 degree Celsius.

Indoor unit quiet operation

Indoor unit quiet operation
Your peace is here to stay with Daikin air conditioners indoor unit quiet operation. It optimises the airflow speed according to low noise level to give an uninterrupted comfort you desire. Switch on your Daikin AC and enjoy peaceful air conditioning experience.

Self-diagnosis

Self-diagnosis
The machine auto detects the error and shows the related code on the remote screen. Now you can easily self diagnose the error and report it to your Daikin authorised service centre for a quick resolution.

Specification

Model nameIndoor unitGTHT35TV16XZGTHT50TV16UZGTHT60TV16UZ
Outdoor unitRHTG35TV16XZRHTG50TV16UZRHTG60TV16UZ
Power supply1 50Hz 230V1 50Hz 230V1 50Hz 230V
(220-240V)(220-240V)(220-240V)
Power supply intakeOutdoor unitOutdoor unitOutdoor unit
Cooling capacity Rated Full/Half (min.~max.)kW3.5/1.75 (1.75~3.5)5.0/2.5 (2.5~5.0)6.0/3.0(2.5~6.0)
Btu/h11900/6000 (6000~11900)17100/8500 (8500~17100)20500/10240 (8500~20500)
Heating capacity Rated Full/Half (min.~max.)kW3.5/1.75 (1.75~3.5)5.0/2.5 (2.5~5.0)5.5/2.75(2.5~5.5)
Btu/h11900/6000 (6000~11900)17100/8500 (8500~17100)18800/9400 (8500~18800)
Power consumption Rated Full/Half (min.~max.)CoolingW1110 /468(468-1110)1850/588 (588-1850)1970/780 (588~1970)
HeatingW1110 /468(468-1110)1850/588 (588-1850)1700/700 (588~1700)
EERCoolingW/W3.152.703.05
Voltage RangeCoolingV160-265160-265160-265
HeatingV160-265160-265160-265
Operating currentCoolingA4.878.158.67
HeatingA4.878.157.48
Indoor unit
Panel colourWhiteWhiteWhite
Dimensions HxWxDmm283x800x198298x885x229298x885x229
(Package dimensions) (340 x 855 x 265)(375 x 980 x 325)(375 x 980 x 325)
Weight (Gross)kg8 (12)11 (16)11 (16)
Airflow rate *1 X(Y)Coolingm3/min.9.616.216.3
Heatingm3/min.9.616.216.3
Operation sound H/M/ML/L/SLCoolingdBA40/36/32/29/2645/42/40/38/3547/45/43/40/38
HeatingdBA40/36/32/29/2645/42/40/38/3547/45/43/40/38
Outdoor unit
Dimensions (H x W x D)mm550x765x285595x845x300595 x 845 x 300
Package dimensions (H x W x D)mm(642x932x380)(680x1035x410)(680x1035x410)
Weight (Gross)kg27(34)35(43)36(44)
Operation sound H/SLCoolingdBA51/--54/--56/--
HeatingdBA51/--54/--56/--
Refrigerant (Quantity)kgR32(0.56kg)R32 (0.68kg)R32 (1.03kg)
Breaker sizeA152020
Piping lengthCharge-lessm101010
Max. lengthm203030
Max. heightm152020
Piping connectionGas/Liquidmm9.5/ 6.412.7 / 6.412.7 / 6.4
Operation limitCoolingoCDB19.4~5019.4~5019.4~50
HeatingoCDB4~244~244~24
Loading Quantity40 HQ ContainerSets200160160

Measurement conditions:

  • Cooling capacity is based on: indoor temp. 27° CDB, 19° CWB; outdoor temp. 35° CDB, piping length 5 m.
  • Sound levels are based on temperature conditions 1. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

Cooling and heating capacities above are rounded off to first decimal. 1TR (Ton of Refrigeration) = ~3.517 kilowatt.

AS A PART OF CONTINOUS DEVELOPMENT AND UPDGRADATION THE PRODUCT IMAGE/ACCESSORY/FEATURE MAY BE DIFFERENT FROM ACTUAL PRODUCT AT THE TIME OF PURCHASE.